100 A Load Center with T104M Mechanism, 8-Breaker Spaces
Model#T30004R
- Proposition 65 warning for California residents
100 A Load Center with T104M Mechanism, 8-Breaker Spaces
Model#T30004R
- Proposition 65 warning for California residents
- Eight breaker spaces
- Reduces installation costs
- Eliminates the need for additional service panels
- Fits most of our hard-wired T100 mechanical and PE digital timers
- Control two-speed pumps with the T30604R
- Fully compatible with all electrical requirements for pool/spa installations
- Load center dead front has two knockouts and one on the side for switches or GFCIs
- Wiring devices may be installed in these load centers with the use of Standoffs, sold separately
- Distribution/Control Panel
- Motor Control
- Pump Control
Input Voltage Range(s) 208-277 VAC, 60 Hz Number Of Circuits 1 Resistive 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz Switch Type DPST Enclosure Type Outdoor type 3R plastic Maximum Power Consumption (W) 3 W Resistive Load Ratings Ranges 40 A, 120-240 VAC, 60 Hz Warranty Period 1-Year limited CAProp65Message Please see the Warning @ www.P65Warnings.ca.gov Country Of Origin Mexico Inductive 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz Inductive Load Ratings Ranges 40 A, 120-240 VAC, 60 Hz Knockout Dimensions Back (5) 1/2" - 3/4" Knockout Dimensions Bottom (4) 1/2" - 3/4", (3) 1/2", (2) 3/4" - 1" Knockout Dimensions Left (1) 3/4" - 1" Knockout Dimensions Right (1) 1 3/4" x 2 3/4" Load Center Rating Display 100 A, 120-240 VAC, Single Phase, 60 Hz Load Center Ratings 100 A, 120 VAC, 60 Hz, 100 A, 208 VAC, 60 Hz, 100 A, 240 VAC, 60 Hz, Single Phase Mechanism Supply Voltage 240 VAC, 60 Hz Mechanisms (1) T104M Motor Three Phase Ranges 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz Pilot Duty (NO) 1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz Pilot Duty Load Ratings Ranges 1000 VA, 120-240 VAC, 60 Hz Tungsten (NO) 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz Tungsten Range(s) 40 A, 120-240 VAC, 60 Hz Auto Start/Stop False Operating Temperature Max (°C) 54 Operating Temperature Max (°F) 130 Operating Temperature Min (°C) -40 Operating Temperature Min (°F) -40 Product Depth (in) 4.75 Product Depth (mm) 120.7 Product Height (in) 16.875 Product Height (mm) 428.6 Product Width (in) 10.875 Product Width (mm) 276.2 Unit Carton Height (in) 5.13 Unit Carton Length (in) 18.5 Unit Carton Weight (lb) 16.366 Unit Carton Width (in) 13.19