Surge Protective Device, 7-Mode, 120/240 VAC 3Ph High Leg Delta, Type 2, EMI/RFI Filter, Audible Alarm, Form C Contact, Surge Current Rating 100kA
Model#H10S23D1DG2
- Not available for e-commerce purchase
   Proposition 65 warning for California residents Proposition 65 warning for California residents
Surge Protective Device, 7-Mode, 120/240 VAC 3Ph High Leg Delta, Type 2, EMI/RFI Filter, Audible Alarm, Form C Contact, Surge Current Rating 100kA
Model#H10S23D1DG2
- Not available for e-commerce purchase
   Proposition 65 warning for California residents Proposition 65 warning for California residents
- Type 2 surge protection
- Optional audible alarm and dry relay contacts
- 7 Modes of protection
- NFPA 780, UL 96A Lightning system protection compliant
- NEMA 4X enclosure for indoor or outdoor installation
- Individually integrated disconnect TPMOV surge protection technology
- Optional advanced electrical noise filter (UL 1283)
- Blue LED status indicator per phase, red LED service indicator
- UL Listed to ANSI/UL 1449 5th Edition
 
- Distribution Panel
- Service Entrance
 
- Voltage - 120/240 VAC 3-Phase High Leg Delta - Modes of Protection - 7 - Surge Protection Type - 2 - Filter - EMI/RFI Filter - Has LED Remote Contact Audible Alarm - Yes - Maximum Surge Current Rating Per Phase - 100 kA - AC Sinewave Tracking (EMI/RFI) Level - Sinewave tracking (EMI/RFI) level is up to 54 dB from 2 kHz to 100 MHz - CA Prop 65 Message - Please see the Warning @ www.P65Warnings.ca.gov - California Proposition 65 - Lead - Color - Gray - Conduit Size - 3/4" - Country of Origin (Intermatic) - U.S.A. - Diagnostics Indicator - Audible Alarm Indicator, Blue LED Status Indicator Per Phase, Form C Dry Relay Contacts, Red LED Service Indicator - Enclosure Type - NEMA Type 4X - Maximum Continuous Operating Voltage (L-G) - 150 - Maximum Continuous Operating Voltage (L-L) - 300 - Maximum Continuous Operating Voltage (L-N) - 150 - Maximum Continuous Operating Voltage (N-G) - 150 - Maximum Continuous Operating Voltage HG - 300 - Maximum Continuous Operating Voltage HL - 300 - Maximum Continuous Operating Voltage HN - 300 - Maximum Surge Current Rating Per Mode - 50 kA - Nominal Discharge Current - 20 kA - Other Certifications and Compatibilities - 2020 National Electric Code, Article 242 (previously NEC, Art. 285), 700.10 & 708.20, ANSI/IEEE C62.72-2016, ANSI/IEEE C62.41.1, C62.41.2-2002, C62.45-2002, ANSI/IEEE C62.62-2010 environments: Categories: A, B & C, Green Energy, NFPA 780 & UL 96A Lightning protection systems - RoHS Certification - Y - Short Circuit Current Rating - 200 kA - Surge Protection LED Indicator - Yes - Surge Protection Technology - Individually integrated thermal disconnect technology TPMOV - UL Certification - ANSI/UL 1283, cULus - UL Standard - ANSI/UL 1449 5th Edition - Voltage Protection Rating (L-G) - 700 - Voltage Protection Rating (L-L) - 1200 - Voltage Protection Rating (L-N) - 700 - Voltage Protection Rating (N-G) - 700 - Voltage Protection Rating HG - 1200 - Voltage Protection Rating HL - 1800 - Voltage Protection Rating HN - 1200 - Warranty Period - 10-Year limited - Wire Size Max - #10 AWG - Operating Temperature Max (°C) - 80 - Operating Temperature Max (°F) - 176 - Operating Temperature Min (°C) - -40 - Operating Temperature Min (°F) - -40 - Product Depth (in) - 3.29 - Product Depth (mm) - 83.57 - Product Height (in) - 10.59 - Product Height (mm) - 268.99 - Product Width (in) - 5.25 - Product Width (mm) - 133.35 - Unit Carton Height (in) - 4.375 - Unit Carton Length (in) - 12.625 - Unit Carton Weight (lb) - 0.6 - Unit Carton Width (in) - 6.375 - Units Per Pallet - 1 