7 Day 30 Amp
These electronic time switches provide to-the-minute programming for accurate load control and reduced energy costs. Up to 20 set points or events (10 ON/10 OFF or any combination) can be preset to automatically repeat on a weekly or daily basis. The program can be overridden at any time by placing the selector switch in the Manual position. These time switches provide for true 7-day load control with up to 140 operations (70 ON/70 OFF or any combination) each week. Model ET279C provides 20 operations or momentary contact closures of 1 to 8 seconds (ten each or any combination) for two independent circuits.
Specifications
- Case – NEMA 1 – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. NEMA 3R – Drawn steel 9-3/8" (23.8 cm) high, 5-1/2" (14.0 cm) wide, 3-5/8" (9.0 cm) deep in gray finish. Both types include permanently attached side hinged door with lockable hasp. Mounting holes and/or mounting bracket included. Separate grounding terminal. Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechanisms, if desired.
- Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom.
- Optional Enclosures – See Time Switch Cases for optional enclosures.
- Special Voltages and Cycles – ALL models 50 or 60 Hz.
- Switch Rating – 30 Amp Inductive/Resistive, 24 / 120 / 240 / 277 VAC 60 Hz; 20 Amp Resistive, 28 VDC; 1 HP 120 VAC 60 Hz; 2 HP 240 VAC 60 Hz; 5 Amp Tungsten, 120 / 240 / VAC 60 Hz; 20 Amp ballast, 120-277 VAC 60 Hz. ET100C same ratings for 120 Volt loads only. Model ET175C normally closed contact ratings: 10A Resistive/General purpose, 12 - 277VAC; 10A Resistive/General purpose, 28VDC; 3A Ballast, 120 - 277VAC; 1/4 HP, 120 VAC; 1/2 HP, 240 VAC; 30 LRA; 12 FLA; 275 VA pilot duty, 120 - 240 VAC
- Carry-over – Field replaceable “AA” batteries maintain program and accurate time keeping for 3 years minimum. Up front replacement does not require removal of mechanism or field wiring.
- Wiring Terminals – #18 to #10 AWG wire
- Minimum ON/OFF Times – 1 minute
- Maximum ON/OFF Times – 6 days 23 hours 59 minutes
| Model |
Circuits |
Switch |
Clock Voltage |
Amp Rating |
HP Rating |
Enclosure |
|---|
| ET171C | 1 | SPST | 120 | 30 | 1 HP / 2 HP | NEMA1 |
|
| ET173C | 1 | DPST | 120 | 30 | 1 HP / 2 HP | NEMA1 |
|
| ET174C | 1 | DPST | 240 | 30 | 1 HP / 2 HP | NEMA1 |
|
| ET175C | 1 | SPDT | 120 | 10 / 30 | 1 HP / 2 HP | NEMA1 |
|
| ET279C | 2 | SPST | 120 | 30 | 1 HP / 2 HP | NEMA1 |
|
|