24 Hour Electronic (28 set points)

Upgrading to an electronic time switch has never been easier than now with the new ET1100 Series. Features include; Automatic Daylight Saving Time adjustment, multi-volt operation from 120 to 277 VAC, and to-the-minute programming for accurate load control and reduced energy costs. Up to 28 set points or events (14 ON/14 OFF per channel) can be preset to automatically repeat on a daily basis. The program can be overridden at any time. Two industrial grade “AAA” Alkaline batteries provide 3 years minimum program and timing protection.

Specifications

  • Case Options – Standard: NEMA 1 Grey Painted Drawn Steel; ‘R’ Option: NEMA 3R Grey Painted Drawn Steel; ‘PD82’ Option: NEMA 3R Grey High-Impact UV Resistant Polycarbonate Plastic with Clear Cover Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechanisms, if desired.
  • Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom.
  • Optional Enclosures – See Time Switch Cases for optional enclosures.
  • Special Voltages and Cycles – ALL models 50 or 60 Hz
  • Switch Rating – 30 Amp Inductive/Resistive, 24 / 120 / 240 / 277 VAC 60 Hz; 20 Amp Resistive, 28 VDC; 1 HP 120 VAC 60 Hz; 2 HP 240 VAC 60 Hz; 5 Amp Tungsten, 120 / 240 / VAC 60 Hz; 20 Amp ballast,120-277 VAC 60 Hz. ET100C same ratings for 120 Volt loads only. ET1115 models normally closed contact ratings: 10A Resistive/General purpose, 12 - 277VAC; 10A Resistive/General purpose, 28VDC; 3A Ballast, 120 - 277VAC; 1/4 HP, 120 VAC; 1/2 HP, 240 VAC; 30 LRA; 12 FLA; 275 VA pilot duty, 120 - 240 VAC
  • Pulse Feature – 2-Circuit models feature 2-Second pulse option for contactor and bell ringing applications.
  • Auto DST – Automatic Adjustment for Daylight Saving Time (DST)
  • Carry-over – Field replaceable “AAA” batteries maintain program and accurate time keeping for 3 years minimum. Up front replacement does not require removal of mechanism.
  • Wiring Terminals – #18 to #10 AWG wire
  • Minimum ON/OFF Times – 1 minute
  • Maximum ON/OFF Times – 23 hours 59 minutes
Model Circuits Switch Clock Voltage Amp Rating HP Rating Enclosure
ET1105C1SPST120 / 208 / 240 / 277301 HP / 2 HPNEMA1
ET1105CPD821SPST120 / 208 / 240 / 277301 HP / 2 HPNEMA 3R
ET1105CR1SPST120 / 208 / 240 / 277301 HP / 2 HPNEMA 3R
ET1115C1SPDT120 / 208 / 240 / 27710 / 301 HP / 2 HPNEMA1
ET1115CPD821SPDT120 / 208 / 240 / 27710 / 301 HP / 2 HPNEMA 3R
ET1115CR1SPDT120 / 208 / 240 / 27710 / 301 HP / 2 HPNEMA 3R
ET1125C2SPST120 / 208 / 240 / 277301 HP / 2 HPNEMA1
ET1125CPD822SPST120 / 208 / 240 / 277301 HP / 2 HPNEMA 3R
ET1125CR2SPST120 / 208 / 240 / 277301 HP / 2 HPNEMA 3R