Surge Protective Device, 7-Mode, 120/240 VAC 3Ph High Leg Delta, Type 2, EMI/RFI Filter, Surge Current Rating 100kA
Model#H10S23D1DG1
- Proposition 65 warning for California residents
Surge Protective Device, 7-Mode, 120/240 VAC 3Ph High Leg Delta, Type 2, EMI/RFI Filter, Surge Current Rating 100kA
Model#H10S23D1DG1
- Proposition 65 warning for California residents
- Type 2 surge protection
- Optional audible alarm and dry relay contacts
- 7 Modes of protection
- NFPA 780, UL 96A Lightning system protection compliant
- NEMA 4X enclosure for indoor or outdoor installation
- Individually integrated disconnect TPMOV surge protection technology
- Optional advanced electrical noise filter (UL 1283)
- Blue LED status indicator per phase, red LED service indicator
- UL Listed to ANSI/UL 1449 5th Edition
- Distribution Panel
- Service Entrance
Voltage 120/240 VAC 3-Phase High Leg Delta Modes of Protection 7 Surge Protection Type 2 Filter EMI/RFI Filter Has LED Remote Contact Audible Alarm No Maximum Surge Current Rating Per Phase 100 kA AC Sinewave Tracking (EMI/RFI) Level Sinewave tracking (EMI/RFI) level is up to 54 dB from 2 kHz to 100 MHz CA Prop 65 Message Please see the Warning @ www.P65Warnings.ca.gov California Proposition 65 Lead Color Gray Conduit Size 3/4" Country of Origin (Intermatic) U.S.A. Diagnostics Indicator Blue LED Status Indicator Per Phase, Red LED Service Indicator Enclosure Type NEMA Type 4X Maximum Continuous Operating Voltage (L-G) 150 Maximum Continuous Operating Voltage (L-L) 300 Maximum Continuous Operating Voltage (L-N) 150 Maximum Continuous Operating Voltage (N-G) 150 Maximum Continuous Operating Voltage HG 300 Maximum Continuous Operating Voltage HL 300 Maximum Continuous Operating Voltage HN 300 Maximum Surge Current Rating Per Mode 50 kA Nominal Discharge Current 20 kA Other Certifications and Compatibilities 2020 National Electric Code, Article 242 (previously NEC, Art. 285), 700.10 & 708.20, ANSI/IEEE C62.72-2016, ANSI/IEEE C62.41.1, C62.41.2-2002, C62.45-2002, ANSI/IEEE C62.62-2010 environments: Categories: A, B & C, Green Energy, NFPA 780 & UL 96A Lightning protection systems RoHS Certification Y Short Circuit Current Rating 200 kA Surge Protection LED Indicator Yes Surge Protection Technology Individually integrated thermal disconnect technology TPMOV UL Certification ANSI/UL 1283, cULus UL Standard ANSI/UL 1449 5th Edition Voltage Protection Rating (L-G) 700 Voltage Protection Rating (L-L) 1200 Voltage Protection Rating (L-N) 700 Voltage Protection Rating (N-G) 700 Voltage Protection Rating HG 1200 Voltage Protection Rating HL 1800 Voltage Protection Rating HN 1200 Warranty Period 10-Year limited Wire Size Max #10 AWG Operating Temperature Max (°C) 80 Operating Temperature Max (°F) 176 Operating Temperature Min (°C) -40 Operating Temperature Min (°F) -40 Product Depth (in) 3.29 Product Depth (mm) 83.57 Product Height (in) 10.59 Product Height (mm) 268.99 Product Width (in) 5.25 Product Width (mm) 133.35 Unit Carton Height (in) 4.375 Unit Carton Length (in) 12.625 Unit Carton Weight (lb) 0.6 Unit Carton Width (in) 6.375 Units Per Pallet 1