7-Day Mechanical Time Switch, 120 VAC, 60Hz, 2 NO/2 NC, Indoor Metal Enclosure, 3.5 Hour Interval
Model#T7801BC
- Proposition 65 warning for California residents
7-Day Mechanical Time Switch, 120 VAC, 60Hz, 2 NO/2 NC, Indoor Metal Enclosure, 3.5 Hour Interval
Model#T7801BC
- Proposition 65 warning for California residents
- Different ON/OFF programs each day of the week
- True 7-day load control with minimum ON/OFF time of 3 1⁄2 hours
- Separate clock motor terminals for switching loads not on line voltage
- Carry-over automatically rewinds when power resumes
- Minimum of 16-hour carry-over for maintaining preset schedules during power failures
- Available with Type 3R rated outdoor metal enclosure or Type 1 rated indoor metal in gray finish with separate grounding terminal
- Indoor Lighting Control
- Timing/Scheduling ON/OFF
Input Voltage Range(s) 120 VAC, 60 Hz Maximum ON/OFF Operations 28 Minimum ON/OFF Times 3.5 hours Operation Mode 7 day Resistive 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz Switch Type 2 NO/2 NC Application Compatibilities HID, LED Backup Protection Time 16 Hours Backup Restoration Time 1 Hour for Every 2 Hours Without Power Backup Type Spring Wound Carry-over CA Prop 65 Message Please see the Warning @ www.P65Warnings.ca.gov California Proposition 65 Lead Color Gray Country of Origin (Intermatic) FRANCE CSA Certification cCSAus Electronic Ballast 16 A, 277 VAC, 60 Hz Electronic Ballast Load Ratings Ranges 16 A, 277 VAC, 60 Hz Enclosure Type Indoor type 1 metal Has Manual Override Yes Inductive 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz Inductive Load Ratings Ranges 40 A, 120-277 VAC, 60 Hz Maximum Power Consumption (W) 3 W Motor Load Ratings Ranges 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz Number Of Circuits 2 Other Certifications and Compatibilities Green Energy, LED Pilot Duty (NO) 1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz Pilot Duty Load Ratings Ranges 1000 VA, 120-277 VAC, Per Pole, 60 Hz Resistive Load Ratings Ranges 40 A, 120-480 VAC, 60 Hz RoHS Certification X Skipper Wheel Not Included Tungsten (NO) 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz Tungsten Range(s) 40 A, 120-277 VAC, 60 Hz UL Certification cULus Warranty Period 1-Year limited Wire Size Max #8 AWG Wire Size Min #14 AWG Wiring Option Terminals Operating Temperature Max (°C) 54 Operating Temperature Max (°F) 130 Operating Temperature Min (°C) -40 Operating Temperature Min (°F) -40 Product Depth (in) 3.75 Product Depth (mm) 95.25 Product Height (in) 13.125 Product Height (mm) 333.3 Product Width (in) 9 Product Width (mm) 228.9 Unit Carton Height (in) 6.75 Unit Carton Length (in) 15.75 Unit Carton Weight (lb) 9.901 Unit Carton Width (in) 11.75 Units Per Pallet 54